banner

Blog

Oct 14, 2024

High-performance hydrogen gas sensor system based on transparent coaxial cylinder capacitive electrodes and a volumetric analysis technique | Scientific Reports

Scientific Reports volume 14, Article number: 1967 (2024) Cite this article

1304 Accesses

1 Citations

Metrics details

A high-performance H2 gas sensor system based on capacitive electrodes and a volumetric analysis technique were developed. Coaxial capacitive electrodes were fabricated by placing a thin copper rod in the center and by adhering a transparent conductive film on the exterior surface of a graduated cylinder. Thus, H2 from a polymer specimen lowered the water level in the cylinder between the two electrodes, producing measurable changes in capacitance that allowed for the measurement of the H2 concentration emitted from the specimen enriched by H2 under high-pressure conditions. The sensing system detected diffused/permeated hydrogen gas from a specimen and hydrogen gas leaks caused by imperfect sealing. The hydrogen gas sensor responded almost instantly at 1 s and measured hydrogen concentrations ranging from 0.15 to 1500 ppm with controllable sensitivity and a measurable range. In addition, performance tests with polymer specimens used in hydrogen infrastructure verified that the sensor system was reliable; additionally, it had a broad measurement range to four decimal places. The sensor system developed in this study could be applied to detect and characterize pure gases (He, N2, O2 and Ar) by real time measurement.

Hydrogen, which is the ultimate energy source, is exponentially increasing in attention throughout the global energy market due to great prospects for replacing conventional fossil energy sources and reducing harmful COx/NOx emissions1,2,3,4,5,6. Despite being a clean and sustainable source of energy, the explosive and flammable nature of hydrogen must be considered critically in every process, especially when the hydrogen content ranges from 4 to 75% in air7,8. Therefore, the detection of low concentrations of H2 is essential for reducing the danger of explosions caused by the leakage of H2 during production, transportation, storage and use in stationary and mobile applications.

Polymers are widely used as seals in hydrogen infrastructure systems that are exposed to high-pressure (HP) H2 during service9,10,11,12. O-ring sealings, control valves, gaskets, liner materials and non-metallic pipelines are the major application of polymeric materials13,14,15,16,17. In harsh environments with wide temperature changes (− 50 ~ 90 °C) and numerous pressure cycles (0 ~ 90 MPa), H2 leaks can form in different situations, such as seal damage, insufficient contact between seals and equipment, and gas permeation through polymeric seals. Therefore, real-time sensing of hydrogen leaks and in situ measurements of hydrogen concentrations released in the environment are constantly required for hydrogen infrastructure systems and O-ring materials.

Hydrogen gas sensors utilize diverse technologies in which a specific properties of a sensing element changes in the presence of hydrogen gas18,19,20,21,22,23,24,25,26. The property could correspond to thermal conductivity, a work function, catalytic activity, an acoustic detection method, and an optical, mechanical, chemical, or physical property. The sensor system requires a transducer to convert the specific change to an electric signal that can be further processed and analyzed. The advantages and disadvantages of each sensor type have been discussed in other studies20.

In addition, H2 detection methods utilize specific instruments, such as gas chromatograph, mass spectrometer and ionization gas pressure sensor. Gas chromatograph uses columns to separate the gas components of a mixture and different types of detectors and to identify each component. Mass spectrometer identifies gas molecules based on their characteristic deflections by a magnetic field. However, these instruments are relatively large and expensive, require periodic maintenance and have slow sampling processes. Moreover, H2 sensors should satisfy multiple requirements: rapid response, high sensitivity, good selectivity and wide measurable ranges27,28,29,30.

Measurements of effective, high-performance and real time are necessary to overcome the limitations of instrumental methods and enhance the performance of hydrogen sensing. In this work, we propose a H2 sensor system based on a volumetric technique and a combination of a coaxial capacitive electrode and frequency response analyzer (FRA) with a general purpose interface bus (GPIB) interfaced with a personal computer (PC) and diffusion/permeation analysis program. The sensor system developed in this study is effective for measuring hydrogen content, leaks and diffusion. The developed sensor allows us to solve several challenges related to the rapid, temperature/pressure-insensitive, and reliable detection of H2 in the field.

The two techniques developed in this study utilize two different hydrogen HP exposure conditions. One technique is the measurement of hydrogen emissions from specimens by a volumetric method after exposure to HP in a vessel and after subsequent decompression. The other technique is the measurement of permeated hydrogen from specimens by a combined volumetric and differential pressure method with a permeation cell under HP conditions.

Two methods are commonly applied for leakage or permeation tests of polymeric materials, such as nitrile butadiene rubber (NBR), ethylene propylene diene monomer (EPDM), high-density polyethylene (HDPE) and low-density polyethylene (LDPE). These polymeric materials are utilized for gas seals, such as the O-ring and liner material of compressed hydrogen pressure vessels under HP conditions14,31. In this study, we demonstrate the various performance results obtained by this sensor system. For instance, the dual-mode detection of H2 via sorption and diffusion is demonstrated for a polymer membrane. The sensor system is validated by comparison with different methods. Moreover, the sensor system developed in this study can be utilized to detect and characterize other pure gases (He, N2, O2 and Ar) through the real time measurement of pure gases in a polymer. In the conclusion, the feature of the developed gas sensor are reviewed.

In the previous section, we described the two sensing methods for measuring hydrogen leaks, diffusivity and permeability. The diffusivity was obtained using the volumetric system shown in Fig. 1. Thus, we applied Fick’s second diffusion equation. By assuming that hydrogen desorption followed the Fickian diffusion, the concentration \({{\text{C}}}_{{\rm{E}}}({\text{t}})\) of released H2 was expressed as32,33:

where \({\upbeta }_{{\text{n}}}\) is the root of the zeroth-order Bessel function J0(βn) of β1 = 2.40483, β2 = 5.52008,…, β50 = 156.295. Equation (1) are infinite series expansions with two summations. The equation provided the solution for Fick’s second diffusion equation for a cylindrical specimen. In equation, CE = 0 at t = 0 and CE = \({{\text{C}}}_{\infty }\) at t = ∞; \({{\text{C}}}_{\infty }\) is the saturated total H2 concentration at infinite time, i.e., the H2 total uptake; D is the diffusivity; \(\rho\) is the radius and \(l\) is thickness (height) of the cylindrical sample.

Illustration of the volumetric measurement system to measure the gas released by a specimen after exposure to HP gas and subsequent decompression. (a) Specimen exposed to gas in an HP chamber. (b) After decompression in the chamber, the specimen was loaded into a graduated cylinder. The cylinder was partially immersed in a container of water, and hydrogen emission measurements were conducted. Blue in graduated cylinder indicates distilled water.

Because Eq. (1) is complicated one with two infinite summations, we developed a diffusion analysis program that calculated D and \({{\text{C}}}_{\infty }\) using 100 terms in the first summation and 50 terms in the second summation \(({\upbeta }_{50}\)) in Eq. (1). By applying the diffusion analysis program, we analyzed the \({{\text{C}}}_{{\text{E}}}\left({\text{t}}\right)\) data using Eq. (1) and a simplex nonlinear optimization algorithm34,35,36.

Similar to the measurement of the H2 concentration after decompression, as shown in Fig. 1, the diffusivity and permeability were obtained using the permeation cell shown in Fig. 2. We expressed the number of moles of diffusing gas per unit area (A) Q(t) as follows32:

where C0 is the initial concentration of the polymer sheet for 0 < x < l at t = 0, C1 is the concentration at x = 0 in the HP part, and C2 is the concentration at x = l in the low-pressure part. According to the experimental arrangement in the permeation cell, for a specimen with thickness l, the polymer specimen was initially at zero concentration (C0 = 0), and the concentration at the face (x = l) through which the gas diffused was maintained effectively at zero concentration (C2 = 0).

Volumetric analysis system for measuring hydrogen permeation under HP by using a permeation cell and graduated cylinder. The cylinder is the same as that shown in Fig. 1.

The summation with the infinite series expansion in Eq. (2) included 50 terms in the actual calculation. Because the terms above the 50th term were sufficiently small and negligible, i.e., less than 10–5, we developed a dedicated diffusion–permeation analysis program to analyze 50 terms and obtain the diffusion coefficient by Eq. (2). This method was more precise than the time lag (L) method obtained by a simple approximated equation after reaching infinite time \(L = l^{2} /6D\)32.

The permeation was deduced as follows from the linear slope \((\frac{\Delta n}{\Delta t})\) of moles of hydrogen with respect to time:

where A is the gas contact area of the specimen and \(\Delta P\) is the pressure gradient between the feed side and the permeate side in the permeation cell. From the steady-state flow rate, the gas permeability was deduced by Eq. (3).

Figure 3a presents a three-channel volumetric analysis system with three coaxial cylindrical electrodes, three cylinders and an FRA with GPIB interfaced with a PC operating a visual studio program. The FRA for capacitance measurement used a VSP-300 impedance analyzer with a GPIB interface connected to a PC and an automated measurement program. The measurements covering from the low-frequency range to high frequency (from 0.01 Hz to 7 MHz) were performed at an applied voltage of 500 mV using VSP-300. The overall accuracy of the impedance analyzer is less than 1% according to the manufacturer specification, except for at low frequencies below 1 Hz. The impedance value at the same frequency was obtained by averaging after repeated measurements of 400 times at 1 MHz. This sensor system was developed in-house.

(a) System diagram of the three-channel volumetric measurement with three coaxial cylindrical capacitive electrodes in three cylinders and an FRA with a GPIB interfaced with a programmed PC. Blue in graduated cylinder indicates distilled water in the water containers and graduated cylinders. (b) H2 emissions from specimens inside the three cylinders. Left: H2 diffusion in the specimen and desorption outside the specimen, right: TEM image indicating the H2 diffusion path and desorption.

An automated measurement program operated by VSP-300 is developed by Microsoft Visual Studio 2019 for data collection. The program language was written using C#. In our developed program, we could set the parameters through the graphical user interface (GUI), such as number of channel, frequency, number of internal/external measurement, measurement time limit, measuring interval. For the data analysis, we used a diffusion analysis program developed using Visual Studio to calculate D \({\text{and}}\) \({C}_{\infty }\) based on least-squares regression.

Three specimens in Fig. 3a were simultaneously measured by the three-channel system. We could measure further samples by increasing the number of cylinders. A schematic diagram of the three-channel volumetric measurement system is shown in which three cylinders stood in containers filled with distilled water. Three FRA channels connected in parallel were employed for automatic real-time and simultaneous capacitance measurements of the gas–water mixtures in cylinders with three sets of coaxial cylindrical electrodes. Electrodes with different radii were used to evaluate the performance levels of the sensor. Figure 3b shows the H2 emissions from the specimens, with the H2 diffusion path shown by transmission electron microscopy (TEM).

The gas released by each specimen lowered the water level with increasing time. By a programmed capacitor measurements with coaxial cylindrical electrodes and a diffusion analysis program, the diffusion/hydrogen concentrations for the samples were determined. Figure 4a, b, c and d show the entire process for obtaining the hydrogen uptake and diffusion values in the cylindrical NBR polymer specimen:

The process for obtaining the associated equation from precalibration data was as follows. We measured the water level against the capacitance at the corresponding channel; there was decreasing water level in the cylinder without a sample. The change in the capacitance due to the change in water volume was measured by an FRA with electrodes. The position of the water level was measured in units of pixels by a digital camera. Then, a 2nd-order polynomial equation for the correlation between the water volume and capacitance was obtained by quadratic regression with an excellent correlation coefficient of R2 = 0.999, as shown in Fig. 4a.

According to the pre-calibration equation, the capacitance was converted to the water volume (Fig. 4b). The black and blue circles corresponded to the capacitance and water volume, respectively, and they were compared against the elapsed time after decompression.

The water level was converted to the volume of emitted hydrogen gas, which was then converted to hydrogen emission in unit of wt·ppm through Eqs. (4)–(6) (Fig. 4c).

The diffusivity and total uptake (D \({\text{and}}\) \({C}_{\infty }\)) were determined by a diffusion analysis program by Eq. (1) based on the least-square fits. The final H2 content (400.9 wt·ppm) was obtained by compensating for the offset value (120.7 wt·ppm) that was missed due to the time lag (Fig. 4d).

Overall sequence of the acquisition of the diffusion parameters for a cylindrical NBR polymer specimen by using coaxial cylinder capacitive electrodes and an FRA. (a) Pre-calibration result described as a second order polynomial equation between the water volume and capacitance by quadratic regression. (b) Time-dependent water level converted from the capacitance, with black and blue circles corresponding to the capacitance and water volume, respectively. (c) Water volume converted to emitted hydrogen gas volume and then to hydrogen emission in units of wt·ppm through Eq. (3). (d) Diffusivity, D\(,\mathrm{and total uptake},\) \({C}_{\infty }\), determined using a diffusion analysis program and Eq. (5). The blue line in (d) is the total compensated emission curve obtained by restoring the missing content caused by the time lag.

We evaluated the performance of the gas sensing system by utilizing several approaches, including performance testing and validation of the sensor system.

By using volumetric analysis based on the permeation cell and coaxial capacitive electrode (Fig. 2), we monitored the permeation through the specimen and hydrogen leaks caused by fracture. The results provided in Fig. 5 reveal the real-time permeated hydrogen and leakage contents in units of moles of hydrogen versus time after pressurization for cylindrical EPDM specimens. The permeated hydrogen was measured through diffusion from the specimen after reaching a steady state. The small content from the leak caused by fracture in the specimen increased linearly with time.

Permeated hydrogen and leaked hydrogen vs. time after pressurization of a cylindrical specimen of EPDM polymer.

Hydrogen leakage due to permeation through a polymer membrane was measured by the differential pressure method. In Fig. 6, we present the moles of permeated hydrogen vs. time after pressurization for the case of a sheet of EPDM used as a gas seal. The diffusion coefficient and permeation were obtained according to Eqs. (2) and (3), respectively, by applying the diffusion–permeation analysis program. The diffusion coefficient was accurately obtained by Eq. (2) instead of by the approximate time lag method. The gas permeability was obtained from the steady-state flow rate.

Permeation/diffusion measurements for a sheet of EPDM polymer. The slope of the blue line was obtained by the linear data after reaching steady state conditions for a specified number of moles of permeated hydrogen n with regard to time after pressurization.

In previous investigations of the hydrogen diffusion mechanisms of EPDM composites blended with carbon black (CB)37,38, the hydrogen uptake and diffusion characteristics exhibited two types of diffusion: fast diffusion due to H2 absorbed in the polymer network and slow diffusion due to H2 adsorbed physically at the CB filler interface. The diffusion mechanism in CB-filled EPDM represented two diffusion behaviors, as shown in Fig. 7a, which were detected by the H2 gas sensor system developed in this work, as shown in Fig. 1. Figure 7b shows the H2 emission behavior vs. time data. The pressure depending sorption behaviors for pressures reaching 90 MPa were interpreted by the dual-mode model based on two contributions from Henry’s law and the Langmuir model39,40.

(a) Dual-mode H2 diffusion model in a cylindrical specimen of EPDM polymer. The black spheres indicate CB. The blue circles indicate H2. The blue line is the path of H2 diffusion. Left: slow diffusion of H2 adsorbed at the CB–filler interface. Right: fast diffusion of H2 absorbed in the polymer network. (b) Dual-mode emission vs. time in cylindrical EPDM specimens with R = 5.90 mm and H = 2.35 mm after exposure to 8 MPa H2 for 26 h. The offset value included in the hydrogen emission data, is the sum of the dotted blue and dashed black lines corresponding to slow and fast diffusion, respectively.

However, a single H2 diffusion behavior was observed in neat EPDM and HDPE plastic, which corresponded to fast diffusion in the polymer networks. The single-mode behavior for HDPE, as shown in Fig. 8a, was caused by fast H2 diffusion. The hydrogen sorption in Fig. 8b for the case of single diffusion/emission for HDPE linearly increased with increasing pressure, consistent with Henry’s law. The single and dual diffusion behaviors in Figs. 7 and 8 were demonstrated by the hydrogen gas sensing system based on a transparent coaxial capacitive electrode, as shown in Figs. 1 and 3.

Single-mode H2 desorption/diffusion behavior in HDPE: (a) Hydrogen emission vs. time after decompression. The blue line is the compensated value obtained by adding the offset value (23.5 wt·ppm). (b) Linear relationship between hydrogen emission content and pressure following Henry’s law.

The absorption and desorption processes of H2 were reversible in most cases, and they were ascribed to physisorption rather than chemisorption by introducing H2. These investigations were consistent with previous reports suggesting that H2 exposure did not change the chemical structure or chemical interactions in NBR according to nuclear magnetic resonance research41,42. These results were consistent with the analysis from a previous investigation37,43. Because of these investigations, the mechanism of hydrogen sensing could not be described with a series of related chemical equations.

The developed sensor system could be applied to other gases, such as He, N2, O2 and Ar. Similar to H2 sensors, gas sensors were utilized to detect the diffusivity and permeability values of other gases in polymers. The principle and process for sensing the gases were exactly the same irrespective of gas species with different masses per mole for the corresponding gas. For instance, the molar mass of N2 gas was 28.001 g/mol. We tested the corresponding gas uptake and diffusivity levels of He, N2, O2 and Ar (Fig. 9) for polymer specimens to demonstrate the sample applications.

Gas uptake and diffusivity for (a) He, (b) N2, (c) O2 and (d) Ar obtained by the developed capacitive gas sensor in polymer specimens. H and R indicate the thickness and radius, respectively, of the cylindrical specimens.

Furthermore, the diffusion rate of gas in stainless steel was generally very slow at 10–15 m2/s at room temperature, and the gas sorption content in this material was smaller than that in polymer membranes. Thus, it was not easy to measure the permeation parameters in other materials. However, by using the developed sensor system with good sensitivity, the diffusivity of gas in thin sheets of metal with thicknesses of 0.1 mm could be measured and analyzed.

We tested various performance indicators of the sensor system with four kinds of coaxial capacitance electrodes with different R1 and R2 values. The performance indicators included the sensitivity, resolution, stability, measurable range, response time, figure of merit (FOM) and squared correlation coefficient (R2). The sensitivity of the sensor, defined as the change in the capacitance with regard to the change in water volume, was measured through the precalibration process described previously in Fig. 4a. The linear slope in Fig. 4a indicates the sensitivity of the capacitive sensor. The sensitivity of the four electrodes ranged from 9.2 to 21.9 pF/mL. The sensor of a high sensitivity indicates an improved resolution. The resolution implies the minimum measurable value of the water level (∆h = 0.01 cm) that corresponds to the minimum cylinder reading calculated from the pixel measurement by the digital camera. The resolution, which was determined as the mass concentration corresponding to a water level of 0.01 cm, ranged from 0.15 to 1.0 wt·ppm. However, the resolution could be reduced to less than 0.1 wt·ppm with increasing the sample number (or sample mass) or by using a graduated cylinder with a small inner radius R2.

Furthermore, the stability of the sensor system could be defined as the standard deviation obtained by measurement for 24 h after the measurement of hydrogen emission was completed, which amounted to 0.11 ~ 0.20%. The measurable range indicated the maximum allowable concentration per mass in cylinders with volume capacities of 10 mL, 20 mL and 50 mL. The measurable range could be adjusted by changing the sample mass and volume capacity of the cylinder. The response time in the gas sensor was associated with contributions from both water level sensing in graduated cylinder and capacitance measuring instrument including controlled measurement program. Thus, we may describe the response time from following two contributions;

When the gas from specimen in graduated cylinder is emitted, the water level in graduated cylinder immediately decreased without any time delay according to an ideal equation of gas (PV = nRT).

The FRA for capacitance measurement used a VSP-300 impedance analyzer with a GPIB interface connected to a PC and an automated measurement program using Visual Studio. The response time from capacitance measuring instrument controlled by automatic program was associated with the fast repetition frequency of 1 MHz and the number of measurements in one cycle in the FRA used for capacitance measurement. The time needed for the repeated measurements of 400 times at 1 MHz frequency using FRA is less than 0.1 s. In addition, the time resolution obtained finally from the entire system is 0.1 s. Thus, we estimated with a margin the response time did not exceed 1 s. The response time in Table 1 is estimated roughly to ∼1 s. Thus, the response time did not exceed 1 s.

The FOM for performance indicated the standard deviation between the measured data and the values calculated from Eqs. (1) and (2). FOM values less than 1% for the four sensor systems indicated a good consistency between the measured and theoretical values. R2 is the squared correlation coefficient between the capacitance and water volume determined from prec-alibration. The value in R2 (0.99) showed good correlation with linearity between capacitance and water volume. The performance results for the developed hydrogen capacitive sensor system are summarized in Table 1. In addition, we could adjust the measuring range, resolution, and sensitivity values because the specimen number, cylinder volume capacity and sensitivity were changeable. In summary, all performance tests indicated that the four sensors with different specifications were excellent for hydrogen gas sensing. However, we could select a suitable sensor depending on the experimental purpose.

The developed H2 sensor system was validated by comparing its measured values with those measured by different methods. Thus, the hydrogen emission content and diffusivity measured for the same polymer specimen by the electrode capacitive sensor developed in this work were compared with those obtained by other methods. The results obtained by various sensors with different electrode radii were included for comparison. The other methods corresponded to volumetric analysis according to a webcam analysis44, thermal desorption analysis–gas chromatography analysis38, and digital camera analysis36, which were verified in previous studies36,38,44,45. The comparison results for various sensing methods were consistent with each other within the expanded uncertainty level, as shown in Fig. 10.

Comparison of various sensing methods for the (a) H2 emission content and (b) Diffusion coefficient. The four sensor systems indicate the capacitive electrodes with different radii presented in Table 1.

Hydrogen gas sensors could play significant roles in retaining safety and protecting property where H2 was produced, transported, used and stored. Thus, we developed a H2 sensor system based on volumetric measurements using a graduated cylinder with coaxial capacitive electrodes and transparent conductive film. The capacitance changes in the electrodes were related to the changes in water volume due to released hydrogen, resulting in accurate measurements of hydrogen content. By applying a diffusion–permeation analysis program, the developed capacitive hydrogen sensor could detect hydrogen leaks and concentrations with the diffusivity due to permeation from the specimens. The sensor system consisted of a high-pressure chamber, a volumetric analysis system with a graduated cylinder, a permeation cell with a graduated cylinder, coaxial capacitor electrodes and a diffusion–permeation analysis program to measure the hydrogen gas leakage caused by imperfect connecting parts and the concentration, diffusivity, and permeation values of H2 emitted from specimens enriched by H2 under high-pressure conditions.

The H2 sensor system exhibited multiple characteristics: a low detection limit of 0.15 wt·ppm H2 content, a measurable range of 1500 wt·ppm, a stability of 0.11%, and a fast response time of one second. This remarkable performance was enabled by precalibration with automatic capacitance measurements by using a frequency response analyzer, which removed noise by averaging several hundred repetitive measurements with a fast 1 MHz repetition rate. In addition, the insensitivity of the sensor to variations in temperature/pressure enabled its application for gas detection and the characterization of pure gases (He, N2, O2 and Ar) through real time measurements.

The features of the sensor techniques and applications developed in this study are summarized as follows:

This technique could simply evaluate the permeation and diffusion of gas through polymer materials enriched with gas under high-pressure conditions.

This technique was insensitive to gas species and sample shape.

A technique for precise calculations was developed by a diffusion–permeation analysis program.

This technique had an adjustable range, sensitivity and resolution for measurements.

This technique was visual because the processes of gas emission and leaks could be observed by the change of water level.

This technique was independent because it did not involve chemical reactions between the target gas and specimen.

The developed gas sensor can be utilized in the testing of permeation properties, such as leakage and sealing ability of rubber material and O-ring under high pressure for hydrogen fueling stations, gas industry and rubber seal production company. However, for use of real-life hydrogen sensing, the sensing system should be minimized and is portable by using compact capacitance meter and digital camera instead of massive frequency response analyzer.

We used NBR and EPDM polymer specimens as O-ring components in H2 infrastructure systems. Additionally, HDPE samples were used as a liner material for type IV pressure vessels of fuel cell electric vehicle; these liners were included in the assessment of hydrogen sensor performance. The composition and density of the polymer samples were provided in literatures38,46. The shapes and dimensions of specimens are as:

Cylindrical NBR specimens with radii of 5.9 mm and thicknesses of 2.1 mm

Cylindrical EPDM specimens with radii of 5.9 mm and thicknesses of 2.3 mm

HDPE fabricated with antimicrobial technology was utilized in the volumetric experiment. The physical property of the HDPE samples were described previously in literature44. HDPE specimens with the following shapes/dimensions were prepared:

Cylindrical HDPE specimens with radii of 5.9 mm and thicknesses of 2.4 mm

Cylindrical LDPE specimens with radii of 6.5 mm and thicknesses of 2.4 mm

A stainless steel chamber was used to expose specimens to gas at specified HPs and a temperature of 298 K prior to volumetric measurement. Conducting H2 exposure for 24 h was sufficient to attain an equilibrium state for gas sorption. After exposure to HP gas, the valve was opened and the gas in the HP chamber was emitted. After the decompression, the elapsed time was counted from the time, t = 0, which the gas pressure inside HP chamber reached atmospheric pressure. Moreover, the H2 permeation was measured by employing the differential pressure method at the desired constant pressure and a temperature of 298 K on the HP side of the permeation cell. The purities of pure gases in this study were as. H2: 99.99%, He: 99.99%, N2: 99.99%, O2: 99.99% and Ar: 99.99%.

We established two different H2 exposure techniques based on volumetric systems to measure hydrogen diffusion/permeation. One method was the measurement of the hydrogen concentration released from the specimen after exposure to HP and after subsequent decompression38,44,46. Figure 1 shows a volumetric analysis system to measure the content of released H2 at a temperature of 298 K, which consisted of an HP chamber for H2 exposure and a graduated cylinder that was immersed in a water container.

After exposure to gas in the HP chamber and after decompression, a specimen was loaded in the air volume at the upper side in a cylinder, as shown in Fig. 1. The H2 gradually emitted from the specimen lowered the water level in the graduated cylinder after decompression. Therefore, the pressure (\(P)\) and volume (\(V)\) of the gas inside the graduated cylinder changed over time.

The gas in the graduated cylinder followed the ideal equation of gas (PV = nRT), where \(R\) is the gas constant 8.20544 × 10–5 m3·atm/(mol·K), T is the gas temperature in the graduated cylinder, and n is the mole number of H2 gas released in the graduated cylinder. The time dependences of \(P(t)\) and \(V(t)\) of the gas in the cylinder were written as38,44,46:

\({\mathrm{where }P}_{o}\) is the pressure at outside the graduated cylinder, g is the gravitation acceleration, \(\uprho\) is the density of distilled water, \(h(t)\) is the water level (height) in the graduated cylinder, \({V}_{o}\) is the total volume of gas and water in the graduated cylinder measured from the water level in the water container, \({V}_{h}(t)\) is the time-dependent volume of water in the cylinder and \({V}_{s}\) is the sample volume.

The amount of H2 gas emitted by the polymeric specimen was measured by reading the water position \(\left[{V}_{h}\left(t\right)\right]\) against time. Thus, the total mole number [\(n(t\))] of emitted gas was determined by measuring the total gas volume [\(V(t)]\) in the graduated cylinder, i.e., the reduction in the water level, as follows:

\({\mathrm{with\, }n}_{A}\left(t\right)=\frac{{P}_{0}}{R{T}_{0}}{V}_{A}\),\({n}_{H}\left(t\right)=\frac{{P}_{0}}{R{T}_{0}}\left[{V}_{H}(t)+V\left(t\right)\left(\beta (t)-\alpha (t)\right)\right]\)

\(\mathrm{\alpha }(t)=\frac{T(t)-{T}_{0}}{{T}_{0}}\), \(\upbeta (t)=\frac{P(t)-{P}_{0}}{{P}_{0}}\), where \({T}_{0}\) and \({P}_{0}\) are the initial temperature and pressure of the gas in the graduated cylinder, respectively, \(V(t)\) is the sum of the remaining initial air volume (\({V}_{A})\) and the released hydrogen volume \({[V}_{H}\left(t\right)]\); i.e., \(V\left(t\right)={V}_{A}+{V}_{H}\left(t\right)\), \({n}_{A}\) is the initial mole number of air, and \({n}_{H}(t)\) is the time-dependent mole number of hydrogen corresponding to the hydrogen volume increase resulting from the released hydrogen. Thus, \({n}_{H}(t)\) was converted to the concentration of H2 [\(C\left(t\right)]\) emitted per unit mass from the specimen as:

where \({m}_{H2}\)[g/mol] is the molar mass of H2 gas 2.016 g/mol and \({m}_{sample}\) is the mass of the sample. According to Eqs. (5) and (6), the time-dependent mole number of H2 \({n}_{H}(t)\) was converted to the H2 mass concentration [\(C\left(t\right)]\) by scaling with the factor \(k=\left[ \frac{{m}_{H2} }{{m}_{sample}}\right].\) \({n}_{H}(t)\) and \(C\left(t\right)\) were influenced by the fluctuations of temperature and pressure in the laboratory environment. To measure precisely, the variations due to changes in temperature and pressure could be compensated by automatic program according to Eq. (6). That is., the terms, \(V\left(t\right)\left(\beta (t)-\alpha (t)\right),\) indicates the volume change in the \({V}_{H}\left(t\right),\) caused by the temperature and pressure variations. The compensation indicates the application of \(V\left(t\right)\left(\beta (t)-\alpha (t)\right)\) calculation in Eq. (6). The application is automatically conducted by program with temperature and pressure recorded. Thus the insensitivity of the sensor to variations in temperature/pressure indicates application of automatic compensation by program.

The change in the water level due to the release of H2 was monitored by the capacitance of coaxial cylinder capacitor electrodes attached to the graduated cylinder. Moreover, the other H2 sensing system for obtaining the hydrogen leak, diffusivity, and permeability values was based on the differential pressure method47, which is called the time lag method under HP conditions; the method involved a permeation cell and a volumetric analysis technique, as shown in Fig. 2. The permeation cell was composed of a feed side under HP conditions and a permeated side under low-pressure conditions that were bordered by a polymer specimen that was serially connected through a stainless steel tube to a graduated cylinder to measure permeated H2. The change in water volume in the cylinder due to permeated H2 was monitored by the capacitance change in the electrode at 298 K. The principle and method used to obtain the number of moles of permeated H2 [\(n\left(t\right)]\) from the water volume were the same as those given in Eqs. (5) and (6) and Fig. 1. The change in the water level due to permeated hydrogen was monitored by the capacitance of coaxial cylinder capacitor electrodes attached to the cylinder.

To measure the capacitance change caused by the change in water volume in the cylinder, we used capacitive electrodes. Thus, the capacitive sensor was designed with coaxial cylindrical electrodes (electrodes 1 and 2) mounted at the center and outside faces of a cylinder; the cylinder was an acrylic tube (dielectric tube wall), as shown in Fig. 11a. A solid cylindrical conductor made of thin copper wire was used as electrode 1. A transparent thin film made of indium tin oxide (ITO), which was attached to the outside the cylinder, was used as electrode 2. A water–gas mixture filled the space between the two coaxial electrodes in the cylinder (Fig. 11b), where the blue and empty white spaces in the cylinder were occupied by water and gas, respectively. Photographs of the capacitor electrode (CE) and graduated cylinder are shown in Fig. 11c. The dielectric constant of water was 78.4 at 298 K48, which was larger than that of gas in a cylinder at 298 K. Thus, by using coaxial capacitive electrodes with good sensitivity, we detected the change in the water–gas volume that changed capacitance. The capacitance change \(\Delta C\) with regard to the water level in the cylinder filled with a water–gas mixture was expressed by the following equations 49:

where L is the axial length of the cylindrical capacitor, R1 is the inner radius of electrode 1, R2 is the inner radius of the coaxial cylinder shell (electrode 2), and \({\varepsilon }_{0, } {\varepsilon }_{{\text{w}}}\) and \({\varepsilon }_{{\text{g}}}\) are the permittivities of free space, water and gas, respectively.

(a) Schematic structure of the coaxial capacitor electrode consisting of electrode 1 and electrode 2. (b) CE locations on the graduated cylinder immersed partially in the water container. (c) Photograph of electrode 1 and the transparent ITO thin film (electrode 2) attached to the external side of the cylinder. For clarity, transparent electrode 2 is indicated in blue.

For a fixed configuration with a coaxial cylindrical electrode, the second term on the right side of Eq. (7) was constant. Thus, \(\Delta C\) was linearly proportional to the change in the water level, h. Thus, we determined the water level corresponding to the capacitance change with a pre-calibration equation of the relationship between the water level and the measured capacitance. From the water volume, we obtained the H2 concentration \(C\left(t\right)\) according to Eqs. (5) and (6).

We fabricated four coaxial capacitance electrodes with different R1 and R2 values to discern any difference in their performance levels regarding sensitivity and stability. The results of the performance test were already presented in Table 1.

The sensor used in previous study is semi-cylindrical capacitance sensor36. The sensor fabricated with two semi-cylindrical electrodes mounted outside of an acrylic tube. An acrylic tube surrounded by two semi-cylindrical electrodes is filled with water–gas. The electrode attached to the outer wall of the acrylic tube is made of copper cylinder with a thickness of 1 mm.

Regarding comparison between two sensors, the hydrogen gas sensor by employing coaxial cylinder capacitive electrodes used in this work is superior to semi-cylindrical capacitance sensor, in views of sensitivity and resolution. The sensitivity and resolution in coaxial cylindrical capacitance sensor are ten times better than those in semi-cylindrical capacitance sensor. Thus this is reason why we have employed coaxial cylinder capacitance sensor in this study. However, the measurable range, stability and response time are almost similar with each other.

The data used to support the findings of this study are available from the corresponding author upon request.

Xie, H. et al. Thermodynamic study for hydrogen production from bio-oil via sorption-enhanced steam reforming: Comparison with conventional steam reforming. Int. J. Hydrog. Energy 42, 28718–28731 (2017).

Article CAS Google Scholar

Dell, R. M. Hydrogen as an energy vector in the 21st century. In Electrochemistry in Research and Development (eds Kalvoda, R. & Parsons, R.) 73–93 (Springer US, 1985).

Chapter Google Scholar

Wang, Z., Li, Z., Jiang, T., Xu, X. & Wang, C. Ultrasensitive hydrogen sensor based on Pd(0)-loaded SnO2 electrospun nanofibers at room temperature. ACS Appl. Mater. Interfaces 5, 2013–2021 (2013).

Article CAS PubMed Google Scholar

Ma, C. & Wang, A. Optical fiber tip acoustic resonator for hydrogen sensing. Opt. Lett. 35, 2043–2045 (2010).

Article ADS CAS PubMed Google Scholar

Haija, M. A., Ayesh, A. I., Ahmed, S. & Katsiotis, M. S. Selective hydrogen gas sensor using CuFe2O4 nanoparticle based thin film. Appl. Surf. Sci. 369, 443–447 (2016).

Article ADS CAS Google Scholar

Li, Z. et al. Resistive-type hydrogen gas sensor based on TiO2: A review. Int. J. Hydrog. Energy 43, 21114–21132 (2018).

Article CAS Google Scholar

Liu, N., Tang, M. L., Hentschel, M., Giessen, H. & Alivisatos, A. P. Nanoantenna-enhanced gas sensing in a single tailored nanofocus. Nat. Mater. 10, 631–636 (2011).

Article ADS CAS PubMed Google Scholar

Wang, Z. et al. Fast and highly-sensitive hydrogen sensing of Nb2O5 nanowires at room temperature. Int. J. Hydrog. Energy 37, 4526–4532 (2012).

Article CAS Google Scholar

Nishimura, S. Fracture behaviour of ethylene propylene rubber for hydrogen gas sealing under high pressure hydrogen. Int. Polym. Sci. Technol. 41, 27–34 (2014).

Article Google Scholar

Yamabe, J. & Nishimura, S. Hydrogen-induced degradation of rubber seals. In Gaseous Hydrogen Embrittlement of Materials in Energy Technologies (eds Gangloff, R. P. & Somerday, B. P.) 12–18 (Woodhead Publishing, 2012).

Google Scholar

Aibada, N., Manickam, R., Gupta, K. & Raichurkar, P. Review on various gaskets based on the materials, their characteristics and applications. Int. J. Text. Eng. Process. 3, 12–18 (2017).

Google Scholar

Yu, W., Dianbo, X., Jianmei, F. & Xueyuan, P. Research on sealing performance and self-acting valve reliability in high-pressure oil-free hydrogen compressors for hydrogen refueling stations. Int. J. Hydrog. Energy 35, 8063–8070 (2010).

Article Google Scholar

Sakamoto, J. et al. Leakage-type-based analysis of accidents involving hydrogen fueling stations in Japan and USA. Int. J. Hydrog. Energy 41, 21564–21570 (2016).

Article CAS Google Scholar

Barth, R. R., Simmons, K. L. & Marchi, C. W. S. Polymers for Hydrogen Infrastructure and Vehicle Fuel Systems: Applications, Properties and Gap Analysis (Sandia National Laboratories, 2013).

Book Google Scholar

Honselaar, M., Pasaoglu, G. & Martens, A. Hydrogen refuelling stations in the Netherlands: An intercomparison of quantitative risk assessments used for permitting. Int. J. Hydrog. Energy 43, 12278–12294 (2018).

Article CAS Google Scholar

Li, M. et al. Review on the research of hydrogen storage system fast refueling in fuel cell vehicle. Int. J. Hydrog. Energy 44, 10677–10693 (2019).

Article CAS Google Scholar

Reddi, K., Elgowainy, A. & Sutherland, E. Hydrogen refueling station compression and storage optimization with tube-trailer deliveries. Int. J. Hydrog. Energy 39, 19169–19181 (2014).

Article CAS Google Scholar

Chauhan, P. S. & Bhattacharya, S. Hydrogen gas sensing methods, materials, and approach to achieve parts per billion level detection: A review. Int. J. Hydrog. Energy 44, 26076–26099 (2019).

Article CAS Google Scholar

Hübert, T., Boon-Brett, L., Black, G. & Banach, U. Hydrogen sensors—A review. Sens. Actuators B Chem. 157, 329–352 (2011).

Article Google Scholar

Buvailo, A., Xing, Y., Hines, J. & Borguet, E. Thin polymer film based rapid surface acoustic wave humidity sensors. Sens. Actuators B Chem. 156, 444–449 (2011).

Article CAS Google Scholar

Kim, S. et al. Fabrication and characterization of thermochemical hydrogen sensor with laminated structure. Int. J. Hydrog. Energy 42, 749–756 (2017).

Article CAS Google Scholar

Kim, S. et al. Thermochemical hydrogen sensor based on chalcogenide nanowire arrays. Nanotechnology 26, 145503 (2015).

Article ADS PubMed Google Scholar

Jang, J.-S. et al. Hollow Pd–Ag composite nanowires for fast responding and transparent hydrogen sensors. ACS Appl. Mater. Interfaces 9, 39464–39474 (2017).

Article CAS PubMed Google Scholar

Wu, B., Zhao, C., Xu, B. & Li, Y. Optical fiber hydrogen sensor with single Sagnac interferometer loop based on vernier effect. Sens. Actuators B Chem. 255, 3011–3016 (2018).

Article CAS Google Scholar

Zhang, Y. N. et al. Recent advancements in optical fiber hydrogen sensors. Sens. Actuators B Chem. 244, 393–416 (2017).

Article CAS Google Scholar

Dai, J. et al. Improved performance of fiber optic hydrogen sensor based on WO3-Pd2Pt-Pt composite film and self-referenced demodulation method. Sens. Actuators B Chem. 249, 210–216 (2017).

Article CAS Google Scholar

Tsai, J.-H. & Niu, J.-S. Hydrogen sensing characteristics of AlGaInP/InGaAs enhancement/depletion-mode co-integrated doping-channel field-effect transistors. Int. J. Hydrog. Energy 44, 2053–2058 (2019).

Article CAS Google Scholar

Conte, M., Iacobazzi, A., Ronchetti, M. & Vellone, R. Hydrogen economy for a sustainable development: State-of-the-art and technological perspectives. J. Power Sour. 100, 171–187 (2001).

Article ADS CAS Google Scholar

Hübert, T., Boon-Brett, L., Palmisano, V. & Bader, M. A. Developments in gas sensor technology for hydrogen safety. Int. J. Hydrog. Energy 39, 20474–20483 (2014).

Article Google Scholar

Leonardi, S. G., Bonavita, A., Donato, N. & Neri, G. Development of a hydrogen dual sensor for fuel cell applications. Int. J. Hydrog. Energy 43, 11896–11902 (2018).

Article CAS Google Scholar

Kang, H. M. et al. Effect of the high-pressure hydrogen gas exposure in the silica-filled EPDM sealing composites with different silica content. Polymers 14, 1151 (2022).

Article CAS PubMed PubMed Central Google Scholar

Crank, J. The Mathematics of Diffusion (Oxford University Press, 1975).

Google Scholar

Demarez, A., Hock, A. G. & Meunier, F. A. Diffusion of hydrogen in mild steel. Acta Metall. 2, 214–223 (1954).

Article CAS Google Scholar

Nelder, J. A. & Mead, R. A simplex method for function minimization. Comput. J. 7, 308–313 (1965).

Article MathSciNet Google Scholar

Jung, J. K., Kim, I. G., Kim, K. T., Ryu, K. S. & Chung, K. S. Evaluation techniques of hydrogen permeation in sealing rubber materials. Polym. Test. 93, 107016 (2021).

Article CAS Google Scholar

Jung, J. K. et al. Volumetric analysis technique for analyzing the transport properties of hydrogen gas in cylindrical-shaped rubbery polymers. Polym. Test. 99, 107147 (2021).

Article CAS Google Scholar

Fujiwara, H., Ono, H. & Nishimura, S. Effects of fillers on the hydrogen uptake and volume expansion of acrylonitrile butadiene rubber composites exposed to high pressure hydrogen: Property of polymeric materials for high pressure hydrogen devices (3). Int. J. Hydrog. Energy 47, 4725–4740 (2022).

Article CAS Google Scholar

Jung, J. K., Kim, I. G., Chung, K. S. & Baek, U. B. Gas chromatography techniques to evaluate the hydrogen permeation characteristics in rubber: Ethylene propylene diene monomer. Sci. Rep. 11, 4859 (2021).

Article ADS CAS PubMed PubMed Central Google Scholar

Sander, R., Acree, W. E., De Visscher, A., Schwartz, S. E. & Wallington, T. J. Henry’s law constants (IUPAC recommendations 2021). Pure Appl. Chem. 94, 71–85 (2021).

Article Google Scholar

Kanehashi, S. & Nagai, K. Analysis of dual-mode model parameters for gas sorption in glassy polymers. J. Membr. Sci. 253, 117–138 (2005).

Article CAS Google Scholar

Fujiwara, H., Yamabe, J. & Nishimura, S. Evaluation of the change in chemical structure of acrylonitrile butadiene rubber after high-pressure hydrogen exposure. Int. J. Hydrog. Energy 37, 8729–8733 (2012).

Article CAS Google Scholar

Fujiwara, H. & Nishimura, S. Evaluation of hydrogen dissolved in rubber materials under high-pressure exposure using nuclear magnetic resonance. Polym. J. 44, 832–837 (2012).

Article CAS Google Scholar

Jung, J. K. et al. Filler effects on H2 diffusion behavior in nitrile butadiene rubber blended with carbon black and silica fillers of different concentrations. Polymers 14, 700 (2022).

Article CAS PubMed PubMed Central Google Scholar

Jung, J. K., Kim, K.-T. & Baek, U. B. Simultaneous three-channel measurements of hydrogen diffusion with light intensity analysis of images by employing webcam. Curr. Appl. Phys. 37, 19–26 (2022).

Article ADS Google Scholar

Jung, J. K., Kim, K.-T. & Chung, K. S. Two volumetric techniques for determining the transport properties of hydrogen gas in polymer. Mater. Chem. Phys. 276, 125364 (2022).

Article CAS Google Scholar

Jung, J. K., Kim, I. G., Chung, K. S. & Baek, U. B. Analyses of permeation characteristics of hydrogen in nitrile butadiene rubber using gas chromatography. Mater. Chem. Phys. 267, 124653 (2021).

Article CAS Google Scholar

Macher, J., Hausberger, A., Macher, A. E., Morak, M. & Schrittesser, B. Critical review of models for H2-permeation through polymers with focus on the differential pressure method. Int. J. Hydrog. Energy 46, 22574–22590 (2021).

Article CAS Google Scholar

Archer, D. G. & Wang, P. The dielectric constant of water and debye-hückel limiting law slopes. J. Phys. Chem. Ref. Data 19, 371–411 (1990).

Article ADS CAS Google Scholar

Li, D., Liu, T., Wu, S., Xu, H. & Wu, B. The liquid level measurement of ultra low temperature cylinder based on the relative capacity method in Proceedings of the 2015 4th national conference on electrical, electronics and computer engineering 1061–1066 (Atlantis Press, 2015).

Download references

This study was supported by the New & Renewable Energy Core Technology Program of the Korea Institute of Energy Technology Evalua-tion and Planning (KETEP) and financial resources from the Ministry of Trade, Industry & Energy, Republic of Korea (Development of 70 MPa-class high-performance rubbers and certification standards for hydrogen refueling stations, No. 20223030040070). This research was supported by the Development of Reliability Measurement Technology for Hydrogen Refueling Station funded by the Korea Research Insti-tute of Standards and Science (KRISS - 2024 - GP2024 - 0010).

Hydrogen Energy Materials Research Team, Korea Research Institute of Standards and Science, Daejeon, 34113, Korea

Jae K. Jung & Ji H. Lee

Department of Measurement Science, University of Science and Technology, 217 Gajeong-ro, Yuseong-gu, Deajeon, 34113, Korea

Ji H. Lee

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

Conceptualization, J.K.J.; validation, J.H.L.; data curation, J.K.J. and J.H.L.; writing—original draft preparation, J.K.J. and J.H.L.; writing—review and editing, J.K.J.; All authors have read and agreed to the published version of the manuscript.

Correspondence to Jae K. Jung.

The authors declare no competing interests.

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

Jung, J.K., Lee, J.H. High-performance hydrogen gas sensor system based on transparent coaxial cylinder capacitive electrodes and a volumetric analysis technique. Sci Rep 14, 1967 (2024). https://doi.org/10.1038/s41598-024-52168-3

Download citation

Received: 09 September 2023

Accepted: 15 January 2024

Published: 23 January 2024

DOI: https://doi.org/10.1038/s41598-024-52168-3

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

SHARE